How to Use an AED: Pad Placement, Wet Chests and Safety
Why does speed matter so much?
Because survival falls sharply with every minute that passes before defibrillation. An AED is the single intervention most likely to restart a heart in cardiac arrest, and compressions buy time until it arrives rather than replacing it.
This is why retrieval is drilled as hard as operation. A team that knows exactly where the cabinet is and who fetches it saves more time than a team that performs textbook compressions while someone searches the building.
What are the steps?
Power on, expose the chest, dry it if wet, apply pads upper right and lower left, let the unit analyse without anyone touching the victim, call clear, deliver the shock if advised, then resume compressions immediately.
- Power on first. The unit talks you through the rest, so turn it on before anything else.
- Expose and dry. Clothing off, chest wiped. This is where aquatic settings differ from most training rooms.
- Pads on. Upper right below the collarbone, lower left below the armpit, following the diagram on the pads.
- Clear for analysis. Nobody touching, including whoever is holding the head.
- Shock, then compress. Resume compressions immediately rather than pausing to look for a response.
What about a wet chest?
Dry it before applying pads. Surface water can carry current across the skin instead of through the heart, reducing effectiveness. Wipe the chest with a towel, but do not delay by moving the victim to a dry area first.
This matters more in aquatic settings than anywhere else, and it is the detail pool staff most often miss because generic CPR courses train on dry manikins. Keeping a towel with the AED is a small change that removes the hesitation entirely.
What is the safety call?
Before analysis and before the shock, look along the victim from head to foot and say clearly that everyone should stand clear. Confirm visually that nobody is touching the victim, including anyone kneeling at the airway.
Say it loudly and look while you say it. The common error is calling clear while facing the machine, which means the announcement is made but never verified.
Adults, children and infants
Use paediatric pads and settings for children under eight where available. If only adult pads are on hand, use them, but place one pad on the chest and one on the back so the pads do not touch each other.
An AED is safe to use on a child. Hesitating because the pads are the wrong size is more dangerous than proceeding with what you have.
Where do you learn this properly?
AED operation is taught and tested as part of professional rescuer CPR, using training units that mirror the prompts and timing of real defibrillators.
See the CPR certification page for the course, or How Often Should You Practice CPR Between Certifications? for keeping the skill current afterwards. Clinical guidance is published by the American Heart Association.
How is an AED maintained?
Check the status indicator weekly, confirm pad expiry dates monthly, and replace the battery according to the manufacturer schedule. Keep a spare set of pads with the unit, and a towel for drying a chest.
Expired pads are the most common failure found during inspections. The adhesive degrades and the gel dries, which means the pads may not conduct properly at the moment they are needed. Both pads and batteries have printed dates, and both should be on the same check log as the first aid kit.
Assign the check to a named person. An AED that nobody owns is an AED nobody notices has failed its self test.
Where should it be, and who should know?
Mount it where it can be reached within roughly thirty seconds of the furthest point of the deck, in an unlocked cabinet, with clear signage visible from a distance. Every member of staff should be able to point to it without thinking.
Test this by asking a new starter where the AED is. If they hesitate, the signage or the induction has failed, and that hesitation is exactly what costs time in an arrest.
Include the location by name in your emergency action plan, covered in Writing an Emergency Action Plan for a Pool.
What happens after the shock
Resume compressions immediately without pausing to check for signs of life. The AED will prompt the next analysis in about two minutes, and the interval between is compression time that should not be interrupted.
Leave the pads attached. Removing them prevents further analysis and further shocks, and arriving clinicians will often continue using the same unit until they transfer the patient to their own monitor.
Record the number of shocks delivered and the time of the first one, because both matter clinically and neither will be remembered accurately afterwards.
Key points
This guide covers why does speed matter so much, and the practical detail behind it. The summary below is the short version.
- Why does speed matter so much
- What are the steps
- What about a wet chest
- What is the safety call
- Adults, children and infants
- Where do you learn this properly
More guides in this series
These guides all support the CPR certification and are written to be read in any order. Start with whichever question you arrived with.
- Two Rescuer CPR and the Bag Valve Mask
- Child and Infant CPR: What Changes
- How Often Should You Practice CPR Between Certifications?
- Professional Rescuer CPR vs Layperson CPR
The course itself is described on the CPR certification page.
Frequently asked questions
Can you use an AED on a wet victim?
Yes, after drying the chest. Water on the skin can carry current across the surface rather than through the heart, so wipe the chest before applying pads. Do not delay to move the victim somewhere dry.
What if the victim has a lot of chest hair?
Press the pads down firmly first. If they will not adhere, use the spare set to strip the hair by applying and pulling off, then apply the remaining pads.
Do you use adult pads on a child?
Use paediatric pads if available. If not, adult pads are acceptable on a child, placed front and back so they do not touch each other.